Wall Firestop For SLP Series Direct Vent Pipe

Wall Firestop For SLP Series Direct Vent Pipe
  • Wall Firestop For SLP Series Direct Vent Pipe

List Price: 

$58.00

Qty:
Payments Accepted

Product Description

  • Model: SLP-WS

Wall firestop spacer for SLP series direct vent pipe. When penetrating a combustible wall, a wall firestop must be installed. To further prevent drafts, the wall firestop should be caulked with caulk with a minimum of 300ºF continuous exposure rating to seal gaps. A wall shield firestop must be placed on each side of an interior wall. A minimum 1-1/2 in. (38 mm) overlap of attached heat shields must be maintained. Whenever a non-combustible wall is penetrated, the wall shield firestop is only required on one side and no heat shield is necessary.

NOTICE: Treatment of wall firestops and construction of a chimney chase may vary with the type of building. Therefore, you MUST check local building codes to determine the requirements.

Fits Fireplaces Below:

  • Majestic Direct Vent Fireplace Models: Jade, Quartz, Ruby & Trilliant
  • Heatilator Direct Vent Fireplace Models: Eclipse, Ion, Rave, GDST See-Through,
  • Heat-N-Glo Direct Vent Fireplace Models: SL-350, SL-550, SL-750, SL-950, ST-550T, DV3732, Fusion, Metro See-Through, Paloma, Revo, Tiara I, Tiara II & Tiara Petite.

Product Manuals & Downloads

Additional Information

  • Product is [Available] with 54 Units in Stock
  • Manufactured by: Monessen Hearth
  • Condition: New
  • Category: SLP Series Direct Vent Pipe
  • Available at: Fine's Gas
  • Average Delivery Lead Time: 4 days
  • Payments Accepted: American Express, PayPal, Visa, MasterCard & Discover

Reviews

Be the first to write a review. Write a Review
  • Model: SLP-WS

Wall firestop spacer for SLP series direct vent pipe. When penetrating a combustible wall, a wall firestop must be installed. To further prevent drafts, the wall firestop should be caulked with caulk with a minimum of 300ºF continuous exposure rating to seal gaps. A wall shield firestop must be placed on each side of an interior wall. A minimum 1-1/2 in. (38 mm) overlap of attached heat shields must be maintained. Whenever a non-combustible wall is penetrated, the wall shield firestop is only required on one side and no heat shield is necessary.

NOTICE: Treatment of wall firestops and construction of a chimney chase may vary with the type of building. Therefore, you MUST check local building codes to determine the requirements.

Fits Fireplaces Below:

  • Majestic Direct Vent Fireplace Models: Jade, Quartz, Ruby & Trilliant
  • Heatilator Direct Vent Fireplace Models: Eclipse, Ion, Rave, GDST See-Through,
  • Heat-N-Glo Direct Vent Fireplace Models: SL-350, SL-550, SL-750, SL-950, ST-550T, DV3732, Fusion, Metro See-Through, Paloma, Revo, Tiara I, Tiara II & Tiara Petite.
  • Product is [Available] with 54 Units in Stock
  • Manufactured by: Monessen Hearth
  • Condition: New
  • Category: SLP Series Direct Vent Pipe
  • Available at: Fine's Gas
  • Average Delivery Lead Time: 4 days
  • Payments Accepted: American Express, PayPal, Visa, MasterCard & Discover
Be the first to write a review. Write a Review